HTF
Sleeve temperature sensor/cable temperature sensor, with passive output
Application
The HTF is a sleeve cable temperature sensor for measuring the temperature of liquid and gaseous media. E.g. installation with thermowells in liquid media. With sleeve sensor holder + cable tie, the HTF can also be used as a contact sensor.
Technical Data
Measuring range: | - 10 ... +105 °C PVC, LiYY, 2x0.25 mm² - 50 ... +180 °C Silicone, SiHF, 2x0.25 mm² - 50 ... +220 °C Teflon, Li-6Y6Y-0Z, 2x1.0 mm² - 50 ... +350 °C Glass silk/VA braiding Ends stripped, with wire end ferrules Tmax NTC = 150 °C, (NTC1.8k = -40...+125 °C) Tmax LM235Z = 125 °C, Tmax NI1000=180 °C, Tmax KTY = 150 °C) |
Sensors/output: | passive, NI1000, NI1000 TK5000, NTC1.8k, NTC5k, NTC10k, NTC10k PRE, NTC20k, NTC103 AT-2, KTY81-110, KTY81-122, KTY81-210, LM235Z (TCR=10mV/K 2.73V at 0 °C) SAT (Satchwell) |
Connecting cable material: | PVC, silicone, Teflon, GLS/VA braiding |
Circuit type: | 2-, 3- or 4-wire connection |
Measuring current: | see resistance table |
Protective tube (sensor sleeve): | Stainless steel, 1.4571, V4A, Ø = 6mm, NL=50mm (other dimensions optional) |
Connecting cable: | 2m (other lengths optional, |
Insulation resistance: | ≥ 100 MΩ, at 20 °C (500V DC) |
Protection class: | III (according to EN 60 730) |
Protection type: | IP 54 standard, IP 65 moisture-proof rolled/embossed |