ESG-S T-3PH
Three-phase thyristor controller, phase angle control
Application
The ESG-S T-3PH is a three-phase thyristor controller (max. load current 2 to 10A) for controlling larger resistive or inductive loads. The modular compact design and the control with a continuous control signal make these power controllers the perfect actuator for industrial power control. The power section of the thyristor controller consists of two antiparallel connected thyristors, the insulated heat sink and the control electronics.
Technical Data
Load voltage: | 3 x 400V AC, 50/60Hz +/- 15% |
Supply voltage: | internally from the load voltage |
Max. Rated current: | 2-10A |
Rotating field: | self-synchronising |
Load types: | resistive and inductive loads |
Test voltage: | according to VDE 0160 / DIN EN 50178 |
Protection type: | Housing: IP40 Terminals: IP20 (VBG4) any |
Climate resistance: | humidity class FDIN 40040 |
Vibration resistance: | 4g |
Installation: | Can be snapped onto DIN rail system (DIN 46277-3, 35x7,5mm) or screwed onto mounting plate |
Housing: | PA, UL 94 V-0 |
Weight: | 0,50 kg (ESG-S T02,04), 0,60 kg with cooling (ESG-S T06,08, 10) |
Display of operating states: | Operation: LED „gn“ Modulation: 100% LED „gn“ |
Signal contact: | Modulation: 100% 50V AC/2A; 24V DC, 3A |
Inputs: | 0...10V or potentiometer (2.5...10kOhm) (Optional 0-20mA) |
Dimensions WxHxD: | 100 x 75 x 110mm (2,4A) 100 x 100 x 110mm (6,8,10A) |
CE label: | According to the European Low Voltage directive 73/23/EEC and EMC Directive 89/336 EEC f. Industrial sector |
Standards: | VDE 0160, EN 60204, IEC 947-4-2 |
ESG-S T-3PH